null

Smart UPS, 8 kVA, 18 Outlets, Rack/Tower, Out: 120/208V AC , In:208V AC - SU8000RT3UN50TF

  • TRIPP LITE Smart UPS, 8 kVA, 18 Outlets, Rack/Tower, Out: 120/208V AC , In:208V AC - SU8000RT3UN50TF
$9,138.74
in Stock

Quick Search Code: NULL
SKU:
SU8000RT3UN50TF
Add To Quote
Hover over me Tooltip text
Special Instructions:
Price is per individual unit.
Availability:
Drop Ship from Manufacturer

Smart UPS, 8 kVA, 18 Outlets, Rack/Tower, Out: 120/208V AC , In:208V AC - SU8000RT3UN50TF


Description:

Smart UPS, On-Line/Double Conversion, Power Rating 8 kVA, Wattage 6.4 kW, Input Voltage 208V AC, Output Voltage 120V AC, 208V AC, Backup Time (Half/Full Load) 13.5 min/5.5 min, Mounting Rack/Tower, Outlet Type UPS/Surge, Number of Outlets 18, Medical Grade No, NEMA Receptacle Configuration 5-20R, L6-20R, L6-30R, NEMA Plug Configuration 50A (CS8265C), Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 0 msec, Width 18 in, Depth 26 in, Height 5 in, Cord Length 10 ft

Details:

Item : Smart UPS | UPS Type : Online/Double Conversion | Power Rating : 8 kVA | Mounting : Rack/Tower | Wattage : 6.4 kW | Input Voltage : 208V AC | Output Voltage : 120/208V AC | Backup Time (Half/Full Load) : 13.5 min/5.5 min | Outlet Type : UPS/Surge | Medical Grade : No | Number of Outlets : 18 | Input Current : 44.2 A | Standards : CSA, FCC Part 15 Category A, NOM, UL 1778 | Phase : 1 | Ports : Contact Closure, DB9 Serial, EPO, SNMP/Web Slot, USB (HID Enabled) | Display Type : LCD/LED | Special Features : True Online Protection with Pure Sine Wave Output, Extended Runtime Option with BP240V10RT3U, BP240V557C-1PH, BP240V787C-1PH, BP240V1037C-1PH, BP240V1407C-1PH, Hot-Swappable Feature Lets User Replace/Repair UPS without Powering Down Connected Equipment, Use in Economy-Mode Saves Operating Costs, | Fax/Modem Line Protection : No | Includes : BP240V10RT3U External Battery Pack, Four Post Compatible Rack Rail Kit (3 sets), Power, SU5000XFMRT2U Step Down Transformer, SU8000RT3UPM 3U UPS Power Module, SUPDMB710 Detachable PDU with Manual Bypass Switch, Tower Stands for Upright Tower Configuration | Transfer Time : 0 msec | Footnotes : 1,2,3,12,20 | Automatic Volts Regulation : Yes | NEMA Receptacle Configuration : 5-20R, L6-20R, L6-30R | Green Environmental Attribute : Product Contributes To Reducing Energy Consumption | NEMA Plug Configuration : 50A (CS8265C) | Hz : 50/60 Hz | Input Connection : 10 ft Cord with Hubbell CS8265 Plug | Battery Type : Valve Regulated Lead Acid (VRLA) | Operating Elevation (m) : 0-3000 m | DC System Voltage (VDC) : 240 | Output Voltage Regulation (Line Mode) : +/- 2% | Nominal Input Voltage(s) Supported : 208V AC | Nominal Voltage Details : 7200 watts total output supported; 5000 watts maximum 120V output; Add 1 additional SU5000XFMRT2U transformer for full load 120V operation; This configuration requires the Power Module be set to 208V output voltage; included step-down transformer supports 120V output | Primary Form Factor : Rackmount | UPS AC Suppression Response Time : Instantaneous | AC Mode Efficiency Rating (100% Load) : 0.91 | Undervoltage Correction : Corrects undervoltages as low as 100V | Low Voltage Transfer to Battery Power (Setpoint) : 100V | AC Economy Mode Efficiency Rating (100% Load) : 0.96 | Expandable Battery Runtime : Supports extended runtime with optional external battery packs | Network Monitoring Port Description : Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports | UPS Certifications : Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI) | Input Phase : Single-Phase | AC Mode BTU / Hr. (Full Load) : 2732 | Crest Factor : 0.125694444444444 | External Battery Pack Compatibility : BP240V10RT3U ; BP240V787C-1PH | PowerAlert Software : For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert | Output Isolation Transformer : 120V output is isolation transformer protected | Output Circuit Breakers : 20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlets each, 20A single-pole (x4) protect 3 5-15/20R outlets each | Audible Alarm : Unique audible alarms for all major UPS, environmental and power conditions (see manual) | Transfer Time (Economy Mode) : 8 ms. typical power failure response in optional economy mode | Power Factor : 0.9 | Communications Cable : USB, DB9 serial and EPO cables included | Individually Controllable Load Banks : No | Battery Recharge Rate (Included Batteries) : Less than 6 hours from 10% to 90% (typical, full load discharge) | Output kW Capacity (kW) : 7.2 | Installation Form Factors Supported with Included Accessories : 4 post 19 inch rackmount | LED Indicators : 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options | Operating Elevation (ft.) : 0-3000m (0 to 10,000 ft.) | Output Watt Capacity (Watts) : 7200 | Storage Temperature Range : +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius | Switches : 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement | Output Receptacles : (12) 5-15/20R; (4) L6-20R; (2) L6-30R | Frequency Compatibility : 60 Hz | Communications Interface : USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface | Economy Mode Operation : Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes. | UPS Input Connection Type : Hubbell CS8265; Hardwire | Network Management Cards : SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD | Output Voltage Regulation (Economy Line Mode) : +/- 10% | UPS Certification Details : IEC 61000-4-5 1995 B Surge Immunity | Output Volt Amp Capacity (VA) : 8000 | Battery Replacement Description : Hot-swappable, user replaceable external battery packs | Front Panel LCD Display : Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual) | Installation Form Factors Supported with Optional Accessories : 2 post rackmount ( 2POSTRMKITHD ) | WatchDog Compatibility : Supports Watchdog application, OS and hard-reboot restart options for remote applications | EMI / RFI AC Noise Suppression : Yes | Overvoltage Correction : Corrects overvoltages up to 300V | Audible Noise : 60 dBA at front side 1 meter | AC Economy Mode BTU / Hr. (Full Load) : 1024 | Output Voltage Regulation (Battery Mode) : +/- 2% | Frequency Compatibility Details : Output frequency regulation +/- 0.05Hz (free running) | Alarm Cancel Operation : Alarm cancel switch | Cooling Method : Fan | UPS AC Suppression Joule Rating : 2565 | Operating Temperature Range : +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius | Output kVA Capacity (kVA) : 8 | Output AC Waveform (Battery Mode) : Pure Sine wave | Expandable Runtime : Yes | UPS Input Connection Description : 3 wire single phase input (L1, L2, G) | Output Capacity Details : Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less | Rated input current (Maximum Load) : 44.2A (208V) | Voltage Regulation Description : 2% output voltage regulation in standard online, double-conversion mode | Recommended Electrical Service : 208V 50A | UPS Housing Material : Steel | Nominal Output Voltage(s) Supported : 120V; 208V | Output AC Waveform (AC Mode) : Pure Sine wave | Cold Start (Startup in Battery Mode During a Power Failure) : Cold-start operation supported | Included Mounting Accessory Description : 3 sets of adjustable 4 post rack rails included (for separate UPS, transformer and battery pack components); 2-9USTAND tower kit included (supports up to 9U in tower format) | High Voltage Transfer to Battery Power (Setpoint) : 300V | Relative Humidity : 0 to 95%, non-condensing | High Availability UPS Features : Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch | Battery Mode BTU / Hr. (Full Load) : 2432 | Receptacle Detail : 4 x NEMA L6-20R, 2 x NEMA L6-30R, 12 x NEMA 5-15/20R | Form Factor : Rack/Tower | Product Line : SmartOnline | Network Management : SNMP Manageable | Load Capacity : 8000 VA | Additional Information : Ideal for protection of sensitive electronics in any application calling for upright tower or 19 inch rackmount UPS protection, Common applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems | Product Name : SmartOnline SU8000RT3UN50TF 8kVA Tower/Rack-mountable UPS | Package Contents : SU8000RT3UPM 3U UPS Power Module, BP240V10RT3U External Battery Pack, SU5000XFMRT2U Step Down Transformer, SUPDMB710 Detachable PDU with manual bypass switch, Four post compatible rack rail kit (3 sets), Tower stands for upright tower configuration, PowerAlert software, complete data cabling and user manual | Package Includes : SU8000RT3UPM 3U UPS power module;BP240V10RT3U external battery pack;SU5000XFMRT2U step down transformer;SUPDMB710 Detachable PDU with manual bypass switch;Four post compatible rack rail kit (3 sets);Tower stands for upright tower configuration;USB, DB9 and EPO cabling | Product Certifications : IEC 61000; CSA (Canada); NOM (Mexico); UL 1778 | Product Compliance : FCC Part 15 Class A (USA) | Output Capacity (VA) : 8000 | UPS Applications : Mission Critical Applications | Output Capacity (Watts) : 7200 | Battery Mode Heat Dissipation (BTU/Hr) @ Full Load : 2432

Dimensions:

Height : 5 in | Cord Length : 10 ft | Width : 18 in | Depth : 26 in | Rack Height : 8U | UPS Dimensions Details : Includes 3U UPS/power module, 3U battery pack, 2U SU5000XFMRT2U step down transformer plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed | Primary UPS Width (mm) : 445 | Maximum Device Depth (in.) : 32.5 | Primary UPS Depth (mm) : 656 | Primary UPS Height (mm) : 131 | UPS Input Cord Length (ft.) : 10 | Minimum Required Rack Depth (inches) : 37.5 | UPS Power Module Dimensions (hwd, in.) : 5.14 x 17.5 x 25.82 | Stepdown Transformer Dimensions (hwd / in.) : 3.5 x 17.5 x 20.8 | Unit Dimension Details : Includes 3U UPS/power module, 3U battery pack, 2U SU5000XFMRT2U step down transformer plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed


      


LED BUY AND TRY PROGRAM
Our LED buy and try program provides our customers a 100% risk free, way to test any LED before making a larger purchase.

Are you thinking of switching to LEDs but not sure if the LED will work for you? No problem! Buy a few pieces of
what you need to test and then send back what you don't like or purchase more if you do like. You can return any
LED bulb or fixture within 14 days of receiving it for a full refund, including the original $8 shipping charge.
 
LED buy and try program
You will only incur the cost of returning the items to us. Our buy and try program is limited to LED orders under $200 so if you are involved in a larger project please contact us at 1-800-432-7995 or email us sales"at"superiorlighting.com.com prior to placing your order. We will gladly find a way to help you test some items prior to purchasing large quantities. All items returned, must be returned in original manufacturer packaging, and in the same condition that they were received.
 
 
WARRANTY CLAIMS & RETURNS
Our goal is your 100% satisfaction with every order! No hassle 14 days returns.

14-day warranty
We stand behind the products we sell. If for any reason you are not satisfied with a purchase you may return a product within 14 days of receiving it. Please inspect all products upon receipt. If an item arrives broken we will make arrangements to either refund or replace the item for you. Warranty claims can be filed within the stated warranty period of the item. Please contact customer service at 1-800-432-7995 or email help "at" superiorlighting.com to receive a return or warranty claim authorization.
PLEASE DO NOT SHIP ITEMS BACK TO US OR TO OUR MANUFACTURERS WITHOUT PRIOR AUTHORIZATION!
SHIPPING RATES

$9.95 Flat Rate on all ORDERS!
$8 shipping
Orders outside the 48 contiguous United States

Additional shipping and handling charges will apply to orders shipped outside the 48 contiguous United States (including Alaska, Hawaii and other U.S. Territories).

Please Contact Us if you are placing an order outside the Continental US and we will advise you of the shipping charges to that destination.
                                                                                                                                            viewspecsheet.jpg


Smart UPS, 8 kVA, 18 Outlets, Rack/Tower, Out: 120/208V AC , In:208V AC - SU8000RT3UN50TF

Smart UPS, 8 kVA, 18 Outlets, Rack/Tower, Out: 120/208V AC , In:208V AC - SU8000RT3UN50TF

[]