null

UPS System, 10 kVA, 6 Outlets, Rack, Out: 200/208/240V AC , In:200/208/240V AC - SU10000RT3U

  • TRIPP LITE UPS System, 10 kVA, 6 Outlets, Rack, Out: 200/208/240V AC , In:200/208/240V AC - SU10000RT3U
$8,759.99
in Stock

Quick Search Code: NULL
SKU:
SU10000RT3U
Add To Quote
Hover over me Tooltip text
Special Instructions:
Price is per individual unit.
Availability:
Drop Ship from Manufacturer

TRIPP LITE UPS System, 10 kVA, 6 Outlets, Rack, Out: 200/208/240V AC , In:200/208/240V AC - SU10000RT3U


Description:

UPS System, On-Line/Double Conversion, Power Rating 10 kVA, Wattage 9 kW, Input Voltage 200V AC, 208V AC, 240V AC, Output Voltage 200V AC, 208V AC, 240V AC, Backup Time (Half/Full Load) 12.5 min/4.3 min, Mounting Rack, Outlet Type Hardwired, Number of Outlets 6, Medical Grade No, NEMA Receptacle Configuration No Configuration, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 0 msec, Width 18 in, Depth 26 in, Height 5 in, Cord Length No Cord, Display Type LCD/LED

Details:

Item : UPS System | UPS Type : Online/Double Conversion | Power Rating : 10 kVA | Mounting : Rack | Wattage : 9 kW | Input Voltage : 200/208/240V AC | Output Voltage : 200/208/240V AC | Backup Time (Half/Full Load) : 12.5 min/4.3 min | Outlet Type : Hardwired | Medical Grade : No | Number of Outlets : 6 | NEMA Receptacle Configuration : No Configuration | Ports : DB9 Serial, EPO, USB | Standards : UL | Includes : (2) 4-Post Rack Rail Kits, BP240V10RT3U External Battery Pack, Data Cables, PowerAlert Software, SUPDMB710 Detachable PDU with Manual Bypass Switch | Fax/Modem Line Protection : No | Hz : 50/60 Hz | Input Current : 56.1 A | Special Features : Hot-Swappable Batteries | Phase : 1 | Automatic Volts Regulation : Yes | Transfer Time : 0 msec | Display Type : LCD/LED | Green Certification or Other Recognition : Tested to UL1778 (USA), CSA (Canada), CE (European Union), NOM (Mexico), Class A (Emissions) | Housing Color : Black | Operating Temp. Range : 104°F (40°C) | Capacity - Batteries : 10000 VA | Input Connection : Hardwired | Battery Type : Valve Regulated Lead Acid (VRLA) | Output Voltage Regulation (Battery Mode) : +/- 2% | Cold Start (Startup in Battery Mode During a Power Failure) : Cold-start operation supported | Alarm Cancel Operation : Alarm cancel switch | Communications Interface : USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface | Audible Noise : 60 dBA at front side 1 meter | UPS Certifications : Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA) | Primary Form Factor : Rackmount | Network Monitoring Port Description : Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports | Operating Elevation (m) : 0-3000 m | Output AC Waveform (AC Mode) : Pure Sine wave | Cooling Method : Fan | Output Receptacles : (4) L6-20R; (2) L6-30R | UPS AC Suppression Joule Rating : 2565 | WatchDog Compatibility : Supports Watchdog application, OS and hard-reboot restart options for remote applications | AC Economy Mode BTU / Hr. (Full Load) : 1280 | High Availability UPS Features : Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch | High Voltage Transfer to Battery Power (Setpoint) : 300V | Output Voltage Regulation (Line Mode) : +/- 2% | AC Mode BTU / Hr. (Full Load) : 3415 | AC Mode Efficiency Rating (100% Load) : 0.91 | Recommended Electrical Service : 60A | Output AC Waveform (Battery Mode) : Pure Sine wave | UPS Input Connection Description : 3 wire single phase input (L1, L2, G) | External Battery Pack Compatibility : BP240V10RT3U ; BP240V787C-1PH | Output kVA Capacity (kVA) : 10 | Operating Temperature Range : +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius | Battery Replacement Description : Hot-swappable, user replaceable external battery packs | UPS AC Suppression Response Time : Instantaneous | Rated input current (Maximum Load) : 56.1A (200V), 54A (208V), 51A (220V), 48.8A (230V), 46.8A (240V) | Output Watt Capacity (Watts) : 9000 | Output Circuit Breakers : 20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlet each | Individually Controllable Load Banks : No | Transfer Time (Economy Mode) : 8 ms. typical power failure response in optional economy mode | Operating Elevation (ft.) : 0-3000m (0 to 10,000 ft.) | UPS Input Connection Type : Hardwire | DC System Voltage (VDC) : 240 | Expandable Battery Runtime : Supports extended runtime with optional external battery packs | Installation Form Factors Supported with Included Accessories : 4 post 19 inch rackmount | Output Voltage Regulation (Economy Line Mode) : +/- 10% | UPS Certification Details : IEC 61000-4-5 1995 B Surge Immunity | Battery Recharge Rate (Included Batteries) : Less than 6 hours from 10% to 90% (typical, full load discharge) | Output Volt Amp Capacity (VA) : 10000 | AC Economy Mode Efficiency Rating (100% Load) : 0.96 | Expandable Runtime : Yes | Front Panel LCD Display : Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual) | Frequency Compatibility : 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion | Crest Factor : 0.125694444444444 | Relative Humidity : 0 to 95%, non-condensing | Nominal Output Voltage(s) Supported : 200V; 208V; 240V | Nominal Input Voltage(s) Supported : 200V AC; 208V AC; 240V AC | UPS Housing Material : Steel | Output kW Capacity (kW) : 9 | Low Voltage Transfer to Battery Power (Setpoint) : 100V | Economy Mode Operation : Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes. | Storage Temperature Range : +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius | Input Phase : Single-Phase | PowerAlert Software : For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert | Undervoltage Correction : Corrects undervoltages as low as 100V | Installation Form Factors Supported with Optional Accessories : 2 post rackmount ( 2POSTRMKITHD ) | Power Factor : 0.9 | Audible Alarm : Unique audible alarms for all major UPS, environmental and power conditions (see manual) | Nominal Voltage Details : Voltage selection via front panel LCD interface | Voltage Regulation Description : 2% output voltage regulation in standard online, double-conversion mode | Network Management Cards : SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD | LED Indicators : 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options | Battery Mode BTU / Hr. (Full Load) : 4593 | Communications Cable : USB, DB9 serial and EPO cables included | Frequency Compatibility Details : Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (No de-rating); Output frequency regulation +/- 0.05Hz (free running) | EMI / RFI AC Noise Suppression : Yes | Overvoltage Correction : Corrects overvoltages up to 300V | Included Mounting Accessory Description : 2 sets of adjustable 4 post rack rails included; 2-9USTAND tower kit included | Switches : 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement | Output Capacity Details : Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less | Software Included : PowerAlert Software | Typical Battery Recharge Time : 8 Hour | Product Line : SmartOnline | Waveform Type : Sine Wave | Additional Information : Switches: Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions, Low voltage transfer to battery power: Maintains continuous operation during undervoltages as low as 156VAC, below this point, output is maintained utilizing battery reserves, High voltage transfer to battery power: Maintains continuous operation during overvoltages to 276V AC, above this point, output is maintained utilizing battery reserves, Cold Start: Yes, inverter can be "cold started" to enable temporary AC output during a power failure, Voltage regulation description: On-line, double-conversion process give this UPS the ability to maintain output voltage within +/-2% of selected nominal voltage at all times | Input Frequency : 60 Hz | Product Name : Smart Online, SU10000RT3U, Expandable 10kVA Tower/Rack-mountable UPS System | Receptacle Detail : 4 x NEMA L6-20R, 2 x NEMA L6-30R | Form Factor : Rack/Tower | Alarm : Backup Operation, DC Bus Fault, Inverter Fault, Output Overload, Over Temperature, UPS Start, Remote Shutdown, Shutdown Complete, Imminent Shutdown, Low Battery | Package Contents : Smart Online, SU10000RT3U, Expandable 10kVA Tower/Rack-mountable UPS System, 3U power module with detachable hot-swap PDU input/output panel and bypass switch, 3U external battery pack, Two sets of 4-post rackmount rails (one for each of the 3U components), One set of tower stands for upright tower con | Status Indicators : LED Display: Line power, Bypass, Inverter, Charger, Output AC, Battery operation | Output Frequency : 60 Hz | Product Color : Black | Network Management : SNMP Manageable | Load Capacity : 10000 VA | Certifications & Standards : Tested to UL1778 (USA), CSA (Canada), CE (European Union), NOM (Mexico), Class A (Emissions) | Maximum Operating Temperature : 104°F (40°C) | Bypass Switch : Manual | Emergency Power OFF : Yes | Thermal Dissipation : 885.66 W | Plug/Connector Type : Hardwired | Battery Mode Heat Dissipation (BTU/Hr) @ Full Load : 4593 | Online Mode Heat Dissipation (BTU/Hr) @ Full Load : 3415 | Output Capacity (Watts) : 9000 | Product Compliance : FCC Part 15 Class A (USA) | Package Includes : SU10000RT3UPM 3U UPS power module;BP240V10RT3U external battery pack;SUPDMB710 Detachable PDU with manual bypass switch;Four post compatible rack rail kit (2 sets);Tower stands for upright tower configuration;USB, DB9 and EPO Cabling | Product Certifications : CSA (Canada); NOM (Mexico); UL 1778 | Output Capacity (VA) : 10000 | UPS Applications : Mission Critical Applications

Dimensions:

Depth : 26 in | Width : 18 in | Cord Length : No Cord | Height : 5 in | Rack Height : 6U | Maximum Device Depth (in.) : 32.5 | Primary UPS Height (mm) : 131 | Primary UPS Depth (mm) : 656 | Minimum Required Rack Depth (inches) : 37.5 | UPS Dimensions Details : Includes 3U UPS/power module, 3U external battery pack plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed | UPS Power Module Dimensions (hwd, in.) : 5.14 x 17.5 x 25.82 | Primary UPS Width (mm) : 445 | Unit Dimension Details : Includes 3U UPS/power module, 3U external battery pack plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed

LED BUY AND TRY PROGRAM
Our LED buy and try program provides our customers a 100% risk free, way to test any LED before making a larger purchase.

Are you thinking of switching to LEDs but not sure if the LED will work for you? No problem! Buy a few pieces of
what you need to test and then send back what you don't like or purchase more if you do like. You can return any
LED bulb or fixture within 14 days of receiving it for a full refund, including the original $8 shipping charge.
 
LED buy and try program
You will only incur the cost of returning the items to us. Our buy and try program is limited to LED orders under $200 so if you are involved in a larger project please contact us at 1-800-432-7995 or email us sales"at"superiorlighting.com.com prior to placing your order. We will gladly find a way to help you test some items prior to purchasing large quantities. All items returned, must be returned in original manufacturer packaging, and in the same condition that they were received.
 
 
WARRANTY CLAIMS & RETURNS
Our goal is your 100% satisfaction with every order! No hassle 14 days returns.

14-day warranty
We stand behind the products we sell. If for any reason you are not satisfied with a purchase you may return a product within 14 days of receiving it. Please inspect all products upon receipt. If an item arrives broken we will make arrangements to either refund or replace the item for you. Warranty claims can be filed within the stated warranty period of the item. Please contact customer service at 1-800-432-7995 or email help "at" superiorlighting.com to receive a return or warranty claim authorization.
PLEASE DO NOT SHIP ITEMS BACK TO US OR TO OUR MANUFACTURERS WITHOUT PRIOR AUTHORIZATION!
SHIPPING RATES

$9.95 Flat Rate on all ORDERS!
$8 shipping
Orders outside the 48 contiguous United States

Additional shipping and handling charges will apply to orders shipped outside the 48 contiguous United States (including Alaska, Hawaii and other U.S. Territories).

Please Contact Us if you are placing an order outside the Continental US and we will advise you of the shipping charges to that destination.
UPS System, 10 kVA, 6 Outlets, Rack, Out: 200/208/240V AC , In:200/208/240V AC - SU10000RT3U

UPS System, 10 kVA, 6 Outlets, Rack, Out: 200/208/240V AC , In:200/208/240V AC - SU10000RT3U

[]