null

UPS System, 6 kVA, 16 Outlets, Rack/Tower, Out: 120/208/240V AC , In:208/240V AC - SU6000RT4UTF

  • TRIPP LITE UPS System, 6 kVA, 16 Outlets, Rack/Tower, Out: 120/208/240V AC , In:208/240V AC - SU6000RT4UTF
$6,483.74
in Stock

Quick Search Code: NULL
SKU:
SU6000RT4UTF
Add To Quote
Hover over me Tooltip text
Special Instructions:
Price is per individual unit.
Availability:
Drop Ship from Manufacturer

UPS System, 6 kVA, 16 Outlets, Rack/Tower, Out: 120/208/240V AC , In:208/240V AC - SU6000RT4UTF


Description:

UPS System, On-Line/Double Conversion, Power Rating 6 kVA, Wattage 5.4 kW, Input Voltage 208V AC, 240V AC, Output Voltage 120V AC, 208V AC, 240V AC, Backup Time (Half/Full Load) 8.5 min/2 min, Mounting Rack/Tower, Outlet Type UPS/Surge, Number of Outlets 16, Medical Grade No, NEMA Receptacle Configuration (2) L6-20R, (2) L6-30R, (4) 5-15R, (8) 5-15/20R, NEMA Plug Configuration 5-15P, Automatic Volts Regulation No, Fax/Modem Line Protection No, Transfer Time 0 msec, Width 18 in, Depth 21 in

Details:

Item : UPS System | UPS Type : Online/Double Conversion | Power Rating : 6 kVA | Mounting : Rack/Tower | Wattage : 5.4 kW | Input Voltage : 208/240V AC | Output Voltage : 120/208/240V AC | Backup Time (Half/Full Load) : 8.5 min/2 min | Outlet Type : UPS/Surge | Medical Grade : No | Number of Outlets : 16 | NEMA Receptacle Configuration : (2) L6-20R, (2) L6-30R, (4) 5-15R, (8) 5-15/20R | Special Features : and PDU, Automatic Inverter Bypass, Cold Start Operation Supported, High Efficiency Economy Mode Operation, Hot Swappable Batteries, Manual Bypass Switch, Schedulable Daily Hours of Economy Mode Operation, UPS | Input Current : 31.9 A | Hz : 60 Hz | Green Environmental Attribute : Product Contributes To Reducing Energy Consumption | Includes : User Manual | Fax/Modem Line Protection : No | Footnotes : Slot for SNMPWEBCARD | Transfer Time : 0 msec | Automatic Volts Regulation : No | NEMA Plug Configuration : 5-15p | Phase : 1 | Display Type : LCD | Ports : Slot for SNMPWEBCARD, USB and RS232 | Standards : UL 1778 | Green Certification or Other Recognition : UL1778FCC Part 15 Category AEC 61000-4-5 1995 B Surge Immunity, RoHS | Capacity - Batteries : 6000 VA/5400 W | Input Connection : NEMA 5-15P Plug | Battery Type : Valve Regulated Lead Acid (VRLA) | Output Watt Capacity (Watts) : 5400 | Cooling Method : Fans | Output Volt Amp Capacity (VA) : 6000 | UPS AC Suppression Joule Rating : 2595 | AC Economy Mode Efficiency Rating (100% Load) : 0.96 | Battery Mode BTU / Hr. (Full Load) : 2279 | High Voltage Transfer to Battery Power (Setpoint) : 280V (full load) / 300V (90% load or less) | Relative Humidity : 0 to 95%, non-condensing | UPS Input Connection Type : L6-30P | Output Circuit Breakers : High voltage 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered; Low voltage 20A breakers protect 4 5-15/20R outlets each; Low voltage 15A breakers protect 2 5-15/20R outlets each | Frequency Compatibility Details : Output frequency regulation +/-0.05Hz (free running) | Nominal Input Voltage(s) Supported : 208V AC; 240V AC | EMI / RFI AC Noise Suppression : Yes | Front Panel LCD Display : Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual) | Communications Cable : USB, DB9 serial and EPO cables included | Network Management Cards : SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD | Primary Form Factor : Rackmount | AC Mode Efficiency Rating (100% Load) : 0.9 | Expandable Runtime : Yes | Input Phase : Single-Phase | Rated input current (Maximum Load) : 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V) | AC Mode BTU / Hr. (Full Load) : 1767 | Recommended Electrical Service : 30A | Output Voltage Regulation (Battery Mode) : +/- 2% | Output Capacity Details : Output capacity de-rates to 4992 watts when used at 208V nominal; Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared | Audible Noise : 60 dBA at front side 1 meter | Output Receptacles : (4) 5-15R; (8) 5-15/20R; (2) L6-20R; (2) L6-30R | UPS Certifications : Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI) | Crest Factor : 0.125694444444444 | Output Receptacle Details : Output receptacles and input line cord are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement | Battery Replacement Description : Hot-swappable, user replaceable batteries | Frequency Compatibility : 60 Hz | Audible Alarm : Unique audible alarms for all major UPS, environmental and power conditions (see manual) | Nominal Input Voltage Description : Factory configured to 208V | Low Voltage Transfer to Battery Power (Setpoint) : 156V (full load) / 100V (50% load or less, derates linearly) | Transfer Time (Economy Mode) : 8ms. typical power failure response in optional economy mode | Cold Start (Startup in Battery Mode During a Power Failure) : Cold-start operation supported | Individually Controllable Load Banks : No | Voltage Regulation Description : Online, double-conversion power conditioning | Communications Interface : USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface | UPS AC Suppression Response Time : Instantaneous | Storage Temperature Range : +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius | Operating Elevation (m) : 0-3000 m | Battery Recharge Rate (Included Batteries) : 6 hours from 10% to 90% (typical, full load discharge) | Output Voltage Regulation (Line Mode) : +/- 2% | Overvoltage Correction : Corrects overvoltages as high as 300V (<90% load) and 280V (full load) | Battery Access : Front panel battery access door | Included Mounting Accessory Description : Two sets of adjustable 4 post 19 inch rackmount installation rails included | High Availability UPS Features : Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch | Switches : Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads. | Operating Temperature Range : +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius | Output AC Waveform (Battery Mode) : Pure Sine wave | Expandable Battery Runtime : Runtime is expandable with external battery packs | Nominal Output Voltage(s) Supported : 120V; 208V; 240V | Installation Form Factors Supported with Optional Accessories : 2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND ) | Output Voltage Regulation (Economy Line Mode) : +/- 10% | Output kVA Capacity (kVA) : 6 | LED Indicators : 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status | WatchDog Compatibility : Yes | Operating Elevation (ft.) : 0-3000m (0 to 10,000 ft.) | Undervoltage Correction : Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly | External Battery Pack Compatibility : BP192V1037C-1PH ; BP192V12-3U ; BP192V1407C-1PH ; BP192V557C-1PH ; BP192V787C-1PH ; BP192V5RT2U (limit 1) | Nominal Voltage Details : This configuration requires the Power Module be set to 208 or 240V output voltage; included step-down transformer supports 120V output (when the voltage-selection switch on the transformer module is set to match the 208 or 240V power module setting) | UPS Housing Material : Steel | Network Monitoring Port Description : Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports | PowerAlert Software : For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert | Internal UPS Replacement Battery Cartridge : RBC5-192 | Output kW Capacity (kW) : 5.4 | Power Factor : 0.9 | Alarm Cancel Operation : Alarm cancel switch | Output AC Waveform (AC Mode) : Pure Sine wave | UPS Certification Details : IEC 61000-4-5 1995 B Surge Immunity | DC System Voltage (VDC) : 192 | AC Economy Mode BTU / Hr. (Full Load) : 768 | Receptacle Detail : 2 x NEMA 5-15/20R, 8 x NEMA 5-15R, 4 x NEMA L6-30R, 2 x NEMA L6-20R | Product Name : SmartOnline EZ SU6000RT4UTF 6000 VA Rack mountable UPS | Form Factor : Rack-mountable | Load Capacity : 6000 VA/5400 W | Emergency Power OFF : Yes | Serial Port : Yes | Network Management : SNMP Manageable | Product Series : EZ | Hot Swappable : Yes | Software Included : PowerAlert Software Suite | Bypass Switch : Manual, Automatic | Package Contents : SmartOnline EZ SU6000RT4UTF 6000 VA Rack mountable UPS, PowerAlert Software Suite CD, Rail Kit, USB Cable, Serial Cable, EPO Cable | USB : Yes | Plug/Connector Type : NEMA L6-30P | Typical Battery Recharge Time : 6 Hour | Product Line : SmartOnline | Certifications & Standards : UL1778, FCC Part 15 Category A, EC 61000-4-5 1995 B Surge Immunity | Output Capacity (VA) : 6000 | Battery Mode Heat Dissipation (BTU/Hr) @ Full Load : 2279 | Installation Form Factors Supported with Included Accessories : 4 post 19 inch rackmount | UPS Applications : Mission Critical Applications | Online Mode Heat Dissipation (BTU/Hr) @ Full Load : 1767 | Product Certifications : IEC 61000; CSA (Canada); UL 1778 | Output Capacity (Watts) : 5400 | Package Includes : SU6000RT4UHVPM hot swappable UPS Power Module;SUPDMB6K Detachable PDU with Maintenance Bypass Switch;SU6000XFMR2U low voltage transformer;1 x 6-ft. USB Cable;1 x 6-ft. DB9 Cable;4-Post Rackmount Hardware (2 sets) | Product Compliance : FCC Part 15 Class A (USA); UKCA

Dimensions:

Height : 7 in | Width : 18 in | Cord Length : No Cord | Depth : 21 in | Rack Height : 6U | Primary UPS Height (mm) : 174 | Stepdown Transformer Dimensions (hwd / in.) : 3.50 x 17.50 x 21.80 | Minimum Required Rack Depth with External Battery Pack (in.) : 28.7 | UPS Input Cord Length (ft.) : 10 | UPS Power Module Dimensions (hwd, in.) : 6.85 x 17.50 x 20.70 | Maximum Device Depth (in.) : 21.8 | Primary UPS Width (mm) : 445 | Primary UPS Depth (mm) : 526 | Minimum Required Rack Depth without External Battery Pack (in.) : 25.7 | Unit Dimensions (hwd / in.) : 10.050 x 17.500 x 21.800 | Minimum Required Rack Depth (inches) : 25


      


LED BUY AND TRY PROGRAM
Our LED buy and try program provides our customers a 100% risk free, way to test any LED before making a larger purchase.

Are you thinking of switching to LEDs but not sure if the LED will work for you? No problem! Buy a few pieces of
what you need to test and then send back what you don't like or purchase more if you do like. You can return any
LED bulb or fixture within 14 days of receiving it for a full refund, including the original $8 shipping charge.
 
LED buy and try program
You will only incur the cost of returning the items to us. Our buy and try program is limited to LED orders under $200 so if you are involved in a larger project please contact us at 1-800-432-7995 or email us sales"at"superiorlighting.com.com prior to placing your order. We will gladly find a way to help you test some items prior to purchasing large quantities. All items returned, must be returned in original manufacturer packaging, and in the same condition that they were received.
 
 
WARRANTY CLAIMS & RETURNS
Our goal is your 100% satisfaction with every order! No hassle 14 days returns.

14-day warranty
We stand behind the products we sell. If for any reason you are not satisfied with a purchase you may return a product within 14 days of receiving it. Please inspect all products upon receipt. If an item arrives broken we will make arrangements to either refund or replace the item for you. Warranty claims can be filed within the stated warranty period of the item. Please contact customer service at 1-800-432-7995 or email help "at" superiorlighting.com to receive a return or warranty claim authorization.
PLEASE DO NOT SHIP ITEMS BACK TO US OR TO OUR MANUFACTURERS WITHOUT PRIOR AUTHORIZATION!
SHIPPING RATES

$9.95 Flat Rate on all ORDERS!
$8 shipping
Orders outside the 48 contiguous United States

Additional shipping and handling charges will apply to orders shipped outside the 48 contiguous United States (including Alaska, Hawaii and other U.S. Territories).

Please Contact Us if you are placing an order outside the Continental US and we will advise you of the shipping charges to that destination.
                                                                                                                                            viewspecsheet.jpg


UPS System, 6 kVA, 16 Outlets, Rack/Tower, Out: 120/208/240V AC , In:208/240V AC - SU6000RT4UTF

UPS System, 6 kVA, 16 Outlets, Rack/Tower, Out: 120/208/240V AC , In:208/240V AC - SU6000RT4UTF

[]